DAR File No. 38680

This rule was published in the August 1, 2014, issue (Vol. 2014, No. 15) of the Utah State Bulletin.


Environmental Quality, Air Quality

Rule R307-347

Large Appliance Surface Coatings

Notice of Proposed Rule

(Amendment)

DAR File No.: 38680
Filed: 07/07/2014 10:03:21 AM

RULE ANALYSIS

Purpose of the rule or reason for the change:

The EPA has indicated that it cannot approve Rule R307-347 as a Reasonable Available Control Technology (RACT) rule as part of Utah's PM2.5 State Implementation Plan (SIP) until it is amended to clarify that the amount of control removal specified in each rule is based on the entire system and the inspection and recordkeeping requirements of the rule are expanded.

Summary of the rule or change:

The rule is amended to require an overall control efficiency of the add-on emission control system of 90%, clarify methodology for determining capture efficiency, and to include additional recordkeeping requirements for the add-on emission control system.

State statutory or constitutional authorization for this rule:

  • Subsection 19-2-104(1)(a)

Anticipated cost or savings to:

the state budget:

There are no new requirements in this proposed rule for the State of Utah; therefore, there are no anticipated costs or savings.

local governments:

There are no new requirements for local government; therefore, there are no anticipated costs or savings.

small businesses:

There are two options to reduce the emissions of VOCs. The first, and more cost-effective, option for small businesses is to use products that meet the VOC limits as specified in Table 1. The other option, which likely only very few larger sources would do, is to use an add-on emission control system that meets the 90% efficiency threshold.

persons other than small businesses, businesses, or local governmental entities:

There are no new requirements for persons other than small businesses, or local government entities; therefore, there are no anticipated costs or savings.

Compliance costs for affected persons:

There are two options to reduce the emissions of VOCs. The first, and more cost-effective option for small businesses, is to use products that meet the VOC limits as specified in Table 1. The other option, which likely only very few larger sources would do, is to use an add-on emission control system that meets the 90% efficiency threshold. It is difficult to determine the cost of installing and operating an add-on emission control system that meets the 90% requirements, as appropriate emission control systems for each source are extremely variable.

Comments by the department head on the fiscal impact the rule may have on businesses:

In most cases businesses will choose to use products that meet the VOC limits in Table 1 of the rule, as that option is usually the most cost-effective. Should a business choose to install and operate an add-on emission control system that meets the 90% overall capture and control efficiency, there would be additional costs to that business. However because appropriate emission control systems for each source are extremely variable, those costs are difficult to predict.

Amanda Smith, Executive Director

The full text of this rule may be inspected, during regular business hours, at the Division of Administrative Rules, or at:

Environmental Quality
Air QualityRoom Fourth Floor
195 N 1950 W
SALT LAKE CITY, UT 84116-3085

Direct questions regarding this rule to:

  • Mark Berger at the above address, by phone at 801-536-4000, by FAX at 801-536-0085, or by Internet E-mail at mberger@utah.gov

Interested persons may present their views on this rule by submitting written comments to the address above no later than 5:00 p.m. on:

09/02/2014

This rule may become effective on:

10/02/2014

Authorized by:

Bryce Bird, Director

RULE TEXT

R307. Environmental Quality, Air Quality.

R307-347. Large Appliance Surface Coatings.

R307-347-1. Purpose.

The purpose of this rule is to reduce volatile organic compound (VOC) emissions from large appliance surface coating operations.

 

R307-347-2. Applicability.

[(1) ]R307-347 applies to sources located in Box Elder, Cache, Davis, Salt Lake, Tooele, Utah and Weber counties that have the potential to emit 2.7 tons per year or more of VOC, including related cleaning activities.

[(2) In Box Elder and Tooele counties, R307-347 applies to the following sources:

(a) Existing sources as of February 1, 2013, that have the potential to emit 5 tons per year or more of VOC, including related cleaning activities; and

(b) New sources as of February 1, 2013, that have the potential to emit 2.7 tons per year or more of VOC, including related cleaning activities.

]

R307-347-3. Exemptions.

(1) The requirements of R307-347 do not apply to the following:

(a) Stencil coatings;

(b) Safety-indicating coatings;

(c) Solid-film lubricants;

(d) Electric-insulating and thermal-conducting coatings;

(e) Touch-up and repair coatings; or

(f) Coating application utilizing hand-held aerosol cans.

 

R307-347-4. Definitions.

The following additional definitions apply to R307-347:

"Air dried coating" means coatings that are dried by the use of air or a forced warm air at temperatures up to 194 degrees Fahrenheit.

"Baked coating" means a coating that is cured at a temperature at or above 198 degrees Fahrenheit.

"Coating" means a protective, functional, or decorative film applied in a thin layer to a surface. This term often applies to paints such as lacquers or enamels. It is also used to refer to films applied to paper, plastics, or foil.

"Extreme performance coatings" means coatings designed for harsh exposure or extreme environmental conditions.

"Large appliances" means doors, cases, lids, panels, and interior support parts of residential and commercial washers, dryers, ranges, refrigerators, freezers, water heaters, dishwashers, trash compactors, air conditioners, and other similar products.

 

R307-347-5. [Emission Standards]VOC Content Limits.

Each owner or operator shall not apply coatings with a VOC content in excess of the amounts specified in Table 1 or shall use an add-on control device as specified in R307-347-7.

 

TABLE 1

Large Appliance Coating Limitations
(values in pounds VOC per gallon of coating, minus water and
exempt solvents(compounds not classified as VOC), as applied)

COATING CATEGORY               VOC [EMISSION RATES]CONTENT LIMITS

                                Baked              Air Dried

General, one component           2.3                  2.3

General, multi-component         2.3                  2.8

Extreme high gloss               3.0                  2.8

Extreme performance              3.0                  3.5

Heat resistance                  3.0                  3.5

Solar absorbent                  3.0                  3.5

Metallic                         3.5                  3.5

Pretreatment coatings            3.5                  3.5

 

R307-347-6. Work Practices and Recordkeeping.

(1) The owner or operator shall:

(a) Store all VOC-containing coatings, thinners, and cleaning materials in closed containers;

(b) Minimize spills of VOC-containing coatings, thinners, and cleaning materials;

(c) Clean up spills immediately;

(d) Convey any coatings, thinners, and cleaning materials in closed containers or pipes;

(e) Close mixing vessels that contain VOC coatings and other materials except when specifically in use; and

(f) Minimize usage of solvents during cleaning of storage, mixing, and conveying equipment.

(2) All sources subject to R307-347 shall maintain records demonstrating compliance with[ all provisions of] R307-347-5 and R307-347-6[ on an annual basis].

(a) Records shall include, but not be limited to, inventory and product data sheets of all coatings and solvents subject to R307-3[52]47.

(b) These records shall be made available to the director upon request.

(3) No person shall apply any coating unless the coating application method achieves a demonstrated 65% transfer efficiency. The following applications achieve a minimum of 65% transfer efficiency and shall be operated in accordance with the manufacturers specifications:

(a) Electrostatic application;

(b) Electrodeposition;

(c) Brush coat;

(d) Flow coat;

(e) Roll coat;

(f) Dip coat;

(g) High-volume, low-pressure (HVLP) spray; or

(h) Other application method capable of achieving at least 65% transfer efficiency, as certified by the manufacturer.

(4) All persons shall perform solvent cleaning operations with cleaning materials having VOC content of 0.21 pounds per gallon or less.

 

R307-347-7. [Optional ]Add-On Control[s]Systems Operations.

[(1) The owner or operator may install and maintain an incinerator, carbon adsorption, or any other add-on emission control device, provided that the emission control device will attain at least 90% efficiency performance.

(2) The owner or operator of a control device shall provide documentation that the emission control system will attain the requirements of R307-347-7.

(3) Emission control systems shall be operated and maintained in accordance with the manufacturer recommendations. The owner or operator shall maintain for a minimum of two years records of operating and maintenance sufficient to demonstrate that the equipment is being operated and maintained in accordance with the manufacturer recommendations.

](1) The owner or operator shall install and maintain an incinerator, carbon adsorption, or any other add-on emission control system, provided that the emission control system is operated and maintained in accordance with the manufacturer recommendations in order to maintain at least 90% capture and control efficiency. Determination of overall capture and control efficiency shall be determined using EPA approved methods, as follows.

(a) The capture efficiency of a VOC emission control system's VOC collection device shall be determined according to EPA's "Guidelines for Determining Capture Efficiency," January 9, 1995 and 40 CFR Part 51, Appendix M, Methods 204-204F, as applicable.

(b) The control efficiency of a VOC emission control system's VOC control device shall be determined using test methods in Appendices A-1, A-6, and A-7 to 40 CFR Part 60, for measuring flow rates, total gaseous organic concentrations, or emissions of exempt compounds, as applicable.

(c) An alternative test method may be substituted for the preceding test methods after review and approval by the EPA Administrator.

(2) The owner or operator of a control system shall provide documentation that the emission control system will attain the requirements of R307-347-7(1).

(3) The owner or operator shall maintain records of key system parameters necessary to ensure compliance with R307-347-7. Key system parameters may include, but are not limited to, temperature, pressure and flow rates. Operator inspection schedule, monitoring, recordkeeping, and key parameters shall be in accordance with the manufacturer's recommendations, and as required to demonstrate operations are providing continuous emission reduction from the source during all periods that the operations cause emissions from the source.

(4) The owner or operator shall maintain for a minimum of two years records of operating and maintenance sufficient to demonstrate that the equipment is being operated and maintained in accordance with the manufacturer recommendations.

 

[R307-347-8. Compliance Schedule.

(1) All sources in Davis and Salt Lake counties are subject to this rule as of the effective date of this rule.

(2) Sources in Box Elder, Cache, Tooele, Utah and Weber counties shall be in compliance with this rule by January 1, 2014.

 

]KEY: air pollution, emission controls, large appliance, surface coating

Date of Enactment or Last Substantive Amendment: [February 1, 2013]2014

Authorizing, and Implemented or Interpreted Law: 19-2-104(1)(a)

 


Additional Information

More information about a Notice of Proposed Rule is available online.

The Portable Document Format (PDF) version of the Bulletin is the official version. The PDF version of this issue is available at https://rules.utah.gov/publicat/bull-pdf/2014/b20140801.pdf. The HTML edition of the Bulletin is a convenience copy. Any discrepancy between the PDF version and HTML version is resolved in favor of the PDF version.

Text to be deleted is struck through and surrounded by brackets ([example]). Text to be added is underlined (example).  Older browsers may not depict some or any of these attributes on the screen or when the document is printed.

For questions regarding the content or application of this rule, please contact Mark Berger at the above address, by phone at 801-536-4000, by FAX at 801-536-0085, or by Internet E-mail at mberger@utah.gov.  For questions about the rulemaking process, please contact the Division of Administrative Rules.