Purpose of the rule or reason for the change:

The EPA has indicated its intention to approve the area source coatings rules for the PM2.5 State Implementation Plan as reasonable available control technology (RACT), but not until: 1) they are amended to clarify that the amount of control removal specified in each rule is based on the entire system, and 2) the inspection and recordkeeping requirements for these systems are expanded. These changes were proposed to this and 13 other air quality area source rules, and a 30-day public comment period was held. During the public comment period, several inquiries were made regarding why the rules do not permit the use of exempt solvents for cleaning. The definition of "volatile organic compound (VOC)" found in Section R307-101-2 incorporates the definition of VOC found in 40 CFR 51.100(s)(1). This definition does permit the use of exempt compounds for cleaning; however, this allowance is not explicitly stated in this or the other proposed area source rules. The change to the proposed rule is to specify that exempt compounds are not VOC by definition.

Summary of the rule or change:

The change clarifies that exempt compounds are not VOC by definition. (DAR NOTE: The original proposed amendment upon which this change in proposed rule (CPR) was based was published in the August 1, 2014, issue of the Utah State Bulletin, on page 23. Underlining in the rule below indicates text that has been added since the publication of the proposed rule mentioned above; strike-out indicates text that has been deleted. You must view the CPR and the proposed amendment together to understand all of the changes that will be enforceable should the agency make this rule effective.)

State statutory or constitutional authorization for this rule:

  • Subsection 19-2-104(1)(a)

Anticipated cost or savings to:

the state budget:

This change is to add clarifying language and does not change any of the rule requirements; therefore, there are no anticipated costs or savings to the state budget.

local governments:

This change is to add clarifying language and does not change any of the rule requirements; therefore, there are no anticipated costs or savings to local government.

small businesses:

This change is to add clarifying language and does not change any of the rule requirements; therefore, there are no anticipated costs or savings to small businesses.

persons other than small businesses, businesses, or local governmental entities:

This change is to add clarifying language and does not change any of the rule requirements; therefore, there are no anticipated costs or savings to persons other than small businesses, businesses, or local government entities.

Compliance costs for affected persons:

This change is to add language to clarify that exempt compounds are not VOC by definition. This change does not result in any additional compliance costs.

Comments by the department head on the fiscal impact the rule may have on businesses:

This change is to add language to clarify that exempt compounds are not VOC by definition. This change will not have a fiscal impact on businesses.

Amanda Smith, Executive Director

The full text of this rule may be inspected, during regular business hours, at the Division of Administrative Rules, or at:

Environmental Quality
Air QualityRoom Fourth Floor
195 N 1950 W
SALT LAKE CITY, UT 84116-3085

Direct questions regarding this rule to:

  • Mark Berger at the above address, by phone at 801-536-4000, by FAX at 801-536-0085, or by Internet E-mail at mberger@utah.gov

Interested persons may present their views on this rule by submitting written comments to the address above no later than 5:00 p.m. on:

This rule may become effective on:

12/01/2014

Authorized by:

Bryce Bird, Director

RULE TEXT

R307. Environmental Quality, Air Quality.

R307-346. Metal Furniture Surface Coatings.

R307-346-1. Purpose.

The purpose of this rule is to limit volatile organic compound (VOC) emissions from metal furniture surface coating operations in application areas, flash-off areas, and ovens of metal furniture coating lines involved in prime and top-coat or single coat operations.

 

R307-346-2. Applicability.

R307-346 applies to sources located in Box Elder, Cache, Davis, Salt Lake, Tooele, Utah and Weber counties that have the potential to emit 2.7 tons per year or more of VOC, including related cleaning activities.

 

R307-346-3. Exemptions.

(1) The requirements of R307-346 do not apply to the following:

(a) Stencil coatings;

(b) Safety-indicating coatings;

(c) Solid-film lubricants;

(d) Electrical-insulating and thermal-conducting coatings;

(e) Touch-up and repair coatings; or

(f) Coating applications utilizing hand-held aerosol cans.

 

R307-346-4. Definitions.

The following additional definitions apply to R307-346:

"Air dried coating" means coatings that are dried by the use of air or a forced warm air at temperatures up to 194 degrees Fahrenheit.

"Application area" means the area where the coating is applied by spraying, dipping, or flow coating techniques.

"Baked coating" means a coating that is cured at a temperature at or above 194 degrees Fahrenheit.

"Coating" means a protective, functional, or decorative film applied in a thin layer to a surface. This term applies to paints, sealants, caulks, inks, adhesives, and maskants.

"Extreme performance coatings" means coatings designed for harsh exposure or extreme environmental conditions.

"Maskants" means a material that protects a metal surface during the etching process.

"Metal furniture coating" means the surface coating of any furniture made of metal or any metal part that will be assembled with other metal, wood fabric, plastic, or glass parts to form a furniture piece.

 

R307-346-5. VOC Content Limits.

Each owner or operator shall not apply coatings with a VOC content in excess of the amounts specified in Table 1 or shall use an add-on control device as specified in R307-346-7.

 

TABLE 1


METAL FURNITURE SURFACE COATING VOC LIMITS
(values in pounds of VOC per gallon of coating, minus water and
exempt solvents (compounds not classified as VOC as defined 
in R307-101-2, as applied)

COATING CATEGORY                   VOC CONTENT LIMITS

                                 Baked          Air Dried

General, One Component            2.3             2.3

General, Multi-Component          2.3             2.8

Extreme High Gloss                3.0             2.8

Extreme Performance               3.0             3.5

Heat Resistant                    3.0             3.5

Metallic                          3.5             3.5

Pretreatment Coatings             3.5             3.5

Solar Absorbent                   3.0             3.5

 

R307-346-6. Work Practices.

(1) The owner or operator shall:

(a) Store all VOC-containing coatings, thinners, and cleaning materials in closed containers;

(b) Minimize spills of VOC-containing coatings, thinners, and cleaning materials;

(c) Clean up spills immediately;

(d) Convey any coatings, thinners, and cleaning materials in closed containers or pipes;

(e) Close mixing vessels that contain VOC coatings and other materials except when specifically in use; and

(f) Minimize usage of solvents during cleaning of storage, mixing, and conveying equipment.

(2) No person shall apply any coating unless the coating application method achieves a demonstrated 65% transfer efficiency.

The following applications achieve a minimum of 65% transfer efficiency and shall be operated in accordance with the manufacturers specifications:

(a) Electrostatic application;

(b) Electrodeposition;

(c) Brush coat;

(d) Flow coat;

(e) Roll coat;

(f) Dip coat;

(g) Continuous coating;

(h) High-volume, low-pressure (HVLP) spray; or

(i) Other application method capable of achieving at least 65% transfer efficiency, as certified by the manufacturer.

(3) All persons shall perform solvent cleaning operations with cleaning material having VOC content (excluding water and solvents exempt from the definition of volatile organic compounds found in R307-101-2) of 0.21 pounds per gallon or less, unless such cleaning operations are performed within the control of the emission control system of R307-346-7.

(4) All sources subject to R307-346 shall maintain records demonstrating compliance with R307-346-5 and R307-346-6.

(a) Records shall include, but not be limited to, inventory and product data sheets of all coatings and solvents subject to R307-346.

(b) These records shall be available to the director upon request.

 

R307-346-7. Add-On Controls Systems Operations.

(1) The owner or operator shall install and maintain an incinerator, carbon adsorption, or any other add-on emission control system, provided that the emission control system is operated and maintained in accordance with the manufacturer recommendations in order to maintain at least 90% capture and control efficiency. Determination of overall capture and control efficiency shall be determined using EPA approved methods, as follows.

(a) The capture efficiency of a VOC emission control system's VOC collection device shall be determined according to EPA's "Guidelines for Determining Capture Efficiency," January 9, 1995 and 40 CFR Part 51, Appendix M, Methods 204-204F, as applicable.

(b) The control efficiency of a VOC emission control system's VOC control device shall be determined using test methods in Appendices A-1, A-6, and A-7 to 40 CFR Part 60, for measuring flow rates, total gaseous organic concentrations, or emissions of exempt compounds, as applicable.

(c) An alternative test method may be substituted for the preceding test methods after review and approval by the EPA Administrator.

(2) The owner or operator of a control system shall provide documentation that the emission control system will attain the requirements of R307-346-7(1).

(3) The owner or operator shall maintain records of key system parameters necessary to ensure compliance with R307-346-7. Key system parameters may include, but are not limited to, temperature, pressure and flow rates. Operator inspection schedule, monitoring, recordkeeping, and key parameters shall be in accordance with the manufacturer's recommendations, and as required to demonstrate operations are providing continuous emission reduction from the source during all periods that the operations cause emissions from the source.

(4) The owner or operator shall maintain for a minimum of two years records of operating and maintenance sufficient to demonstrate that the equipment is being operated and maintained in accordance with the manufacturer recommendations.

 

KEY: air pollution, emission controls, surface coating, metal furniture

Date of Enactment or Last Substantive Amendment: 2014

Authorizing, and Implemented or Interpreted Law: 19-2-104(1)(a)

 


Additional Information

More information about a Notice of Change in Proposed Rule is available online.

The Portable Document Format (PDF) version of the Bulletin is the official version. The PDF version of this issue is available at https://rules.utah.gov/publicat/bull-pdf/2014/b20141101.pdf. The HTML edition of the Bulletin is a convenience copy. Any discrepancy between the PDF version and HTML version is resolved in favor of the PDF version.

Text to be deleted is struck through and surrounded by brackets ([example]). Text to be added is underlined (example).  Older browsers may not depict some or any of these attributes on the screen or when the document is printed.

For questions regarding the content or application of this rule, please contact Mark Berger at the above address, by phone at 801-536-4000, by FAX at 801-536-0085, or by Internet E-mail at mberger@utah.gov.  For questions about the rulemaking process, please contact the Division of Administrative Rules.